Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. Fac. Odontol. Univ. Antioq ; 25(2): 359-371, ene.-jun. 2014. ilus, tab
Article in English | LILACS | ID: lil-712561

ABSTRACT

INTRODUCCIÓN: el objetivo de esta investigación fue valorar si los métodos de Moyers(M) percentil (p) 75, p85, p95 y Tanaka-Johnston(TJ), usados para predecir el diámetro mesiodistal de caninos y premolares no erupcionados, sobreestiman o subestiman el diámetro de sus respectivos sucedáneos. MÉTODOS: estudio de evaluación tecnológica diagnóstica en 56 modelos de yeso de escolares de Medellín, clase I esquelética, incisivos, caninos y bicúspides permanentes erupcionados, seguidos desde 6 a 12 años de edad. Se midió el diámetro mesiodistal de los dientes y se aplicaron los métodos predictivos de Tanaka-Johnston, Moyers p75, p85, p95. Se comparó el valor predicho y el real, utilizando la prueba t-Student relacionada y la de Wilcoxon. La reproducibilidad de los métodos se calculó con los coeficiente de correlación intraclase (CCI) (IC95%), y el nivel, de acuerdo con los límites Bland y Altman al 95%. RESULTADOS: en el arco superior se observaron diferencias significativas con el valor real en las mediciones de T-J y Mp95. En arco inferior todos los métodos fueron diferentes del valor real (p > 0,05), excepto Mp75. La reproducibilidad fue mayor en arco superior con T-J, seguido de Mp85; en el arco inferior el método de Mp75 tuvo mejor reproducibilidad, seguido de Mp85. En arco superior se encontró que T-J sobreestima la medición real en promedio 0,333 mm (IC95% 2,100;1,434), y en el arco inferior Mp75 sobreestima en 2,14 (IC95% -2,020;1,592). CONCLUSIÓN: el mejor método predictivo para el arco superior es el de Tanaka-Johnston, y para el arco inferior es el de Moyers al percentil 75, aunque ambos sobreestiman el valor real, presentan adecuada reproducibilidad.


INTRODUCTION: the objective of this study was to determine whether the methods of Moyers (M) percentile (p) 75, p85, p95 and Tanaka-Johnston (TJ), used in the prediction of the mesiodistal diameter of unerupted canines and premolars, either overestimate or underestimate their respective succedaneous diameter. METHODS: diagnostic technology assessment in 56 plaster models of schoolchildren from Medellin, with class I skeletal and permanent erupted incisors, canines, and bicuspids, with follow-ups from 6 to 12 years of age. The teeth mesiodistal diameter was measured by the predictive methods of Tanaka-Johnston and Moyers p75, p85, p95. The predicted and actual values were evaluated by means of related Student's t test and Wilcoxon test. These methods' reproducibility was calculated by intraclass correlation coefficient (ICC) (95% CI), and their level was calculated using Bland-Altman 95% limits. RESULTS: : in the upper arch, significant actual value differences were observed with the T-J and Mp95 measurements. In the lower arch, the values of all the methods were different to the actual value (p > 0.05), except Mp75. Reproducibility was higher in the upper arch with T-J, followed by Mp85; in the lower arch, Mp75 was the method with the best reproducibility, followed by Mp85. In the upper arch, T-J overestimates the actual measurement by 0,333 mm in average (95% CI 2,100;1,434), and in the lower arch Mp75 overestimates by 2,14 (95% CI-2,020;1,592). CONCLUSSION: the best predictive method for the upper arch is Tanaka-Johnston, and for the lower arch, Moyers at the 75th percentile; although both methods overestimate the actual value, they show adequate reproducibility.


Subject(s)
Tooth, Unerupted , Bicuspid , Cuspid , Dentition, Mixed
SELECTION OF CITATIONS
SEARCH DETAIL